2 Phase
CD Automation Industrial SSR and Thyristor Units
A range of power units to switch 2-phase loads. Ideally suited for normal or variable resistive loads and transformer & inductive load types.
For simple on/off type firing with a DC logic input, choose the REVO S (RS2). If a time proportioned burst firing with a DC linear input is required, try REVO M (RM2) with front panel display & RS485 comm’s as standard.
You can view our product range by choosing the required load type below.
Product range 2 Phase Load Industrial SSR and Thyristor Power Controllers
CD Automation
CD 3000S 2PH
For resistive loads up to 700A (1-2PH)
CD3000S 2PH
- Premium Series 1-2-3PH
- From 10A to 700A
- Max. voltage 480VAC or 600VAC
- cUL us is available as an option
- Heater Break alarm option
CD Automation
REVO E 2PH
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
REVO E 2PH
- From 25 up to 700A
- Max. voltage 480V or 600V AC as option
- Load type: Resistance, Transformer
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Burst Firing, Delay Triggering + Burst Firing (DT)
- N°1 Retransmission is available
CD Automation
CD 3000M 2PH
Universal input signal (SSR, 0-10V, 4-20mA, 10K Pot)
CD3000M 2PH
- Premium Series 1-2-3PH
- From 15A to 700A
- Max. voltage 480VAC or 600VAC
- cUL us is available as an option
- Heater Break alarm option
- Firing Zero Crossing and Burst firing
CD Automation
Multidrive 2PH Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
Multidrive 2PH Thyristor Power Controller
- From 45 up to 2700A
- Max. voltage 480V or 600V & 690V AC as an option
- Load type: Inductive Load, Transformer and Pure Resistance Element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Burst Firing, Delay Triggering + Burst Firing (DT)
- N°4 Retransmission are available plus IO
CD Automation
REVO M 2PH Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
REVO M 2PH Thyristor Power Controller
- From 30 up to 700A
- Max. voltage 480V or 600V AC as option
- (690V available on units > 280A)
- Load type: Resistance, IR Lamp short waveform and SiC element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Heather Break is available as an option.
- Firing mode: Burst Firing as standard
CD Automation
REVO PC Reduce Power Peaks
Modbus RTU, Profibus, Profinet, Modbus TCP, Ethernet IP and other fieldbus
REVO PC Reduce Power Peaks
- Suitable for Normal Resistance and IR Lamp
- To be used with REVO S and REVO Sx
- Firing Mode: SC, HC and Dynamic Burst Firing
- Reduce Peak of Power and let you save Energy
- Modbus RTU, Profibus, Profinet, Modbus TCP, Ethernet IP and other fieldbus
- Heather Break Alarm
CD Automation
REVO S 2PH Thyristor Power Controller
Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
REVO S 2PH Thyristor Power Controller
- From 30 up to 700A
- Max. voltage 480V or 600V AC as option
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Zero Crossing, Burst Firing available with analogue input only
CD Automation
REVO Temperature and Power Controller
Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
REVO TC 2PH Temperature and Power Controller
- Suitable for Normal Resistance
- Three Phase 2PH (2-Leg) From 30A to 210A
- Max. voltage 480V, 600Vac
- Load type: Resistance
- Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
- Heather Break alarm options
- Firing mode: Zero Crossing