CD Automation Archive
Here you will find information about the Sintrol products that are no longer available or have been replaced by new types:
1PH Solid State Relays and Thyristor Power Controllers
CD Automation
CD 3000M 1PH
Universal input signal (SSR, 0-10V, 4-20mA, 10K Pot)
CD3000M 1PH Thyristor Unit
- Premium Series 1-2-3PH
- From 10A to 700A
- Max. voltage 480VAC or 600VAC as an option
- Firing Mode ZC, BF, S+BF, PA and DT
- cUL us is available as an option
- Heater Break alarm option
CD Automation
CD 32000
Universal input signal
CD3200 Thyristor Unit
- Premium Series 1-2-3PH
- From 10A to 700A
- Max. voltage 480VAC or 600VAC as an option
- cUL us is available as an option
- Heater Break alarm option
CD Automation
Multidrive 1PH Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
Multidrive 1PH Thyristor Power Controller
- From 850 up to 2700A
- Max. voltage 480V; 600V or 690V AC as an option
- Load type: Inductive Load, Transformer and MoSi2 element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Delayed Triggering + Burst Firing (DT), Phase Angle (PA) or Soft Start + Phase Angle (S+PA); Current Limit is available with Phase Angle firing
CD Automation
REVO CL Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
REVO CL Thyristor Power Controller
- From 35 up to 700A
- Max. voltage 480VAC or 600VAC as option
- (690V available on units > 280A)
- Load type: Inductive Load, Transformer, UV Lamp and MoSi2 element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Delayed Triggering + Burst Firing (DT), Phase Angle (PA) or Soft Start + Phase Angle (S+PA); Current Limit is available with Phase Angle firing
CD Automation
REVO M 1PH Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
REVO M 1PH Thyristor Power Controller
- From 30 up to 700A
- Max. voltage 480VAC or 600VAC as an option
- (690VAC available on units > 280A)
- Load type: Resistance, IR Lamp short waveform and SiC element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Heather Break is available as an option.
- Firing mode: Burst Firing, Single Cycle & Phase Angle as standard
CD Automation
REVO Temperature and Power Controller
Inputs: Pt100/0, Thermocouple, 0:10V, 4:20mA
REVO TC 1PH Temperature and Power Controller
- Suitable for Normal Resistance load types
- From 30A to 210A
- Max. voltage 480VAC; 600VAC as an option
- Load type: Resistance
- Inputs: Pt100/0, Thermocouple, 0:10V, 4:20mA
- Heater Break alarm option
- Firing mode: Zero Crossing
2PH Solid State Relays and Thyristor Power Controllers
CD Automation
REVO E 2PH
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
REVO E 2PH
- From 25 up to 700A
- Max. voltage 480V or 600V AC as option
- Load type: Resistance, Transformer
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Burst Firing, Delay Triggering + Burst Firing (DT)
- N°1 Retransmission is available
CD Automation
CD 3000M 2PH
Universal input signal (SSR, 0-10V, 4-20mA, 10K Pot)
CD3000M 2PH
- Premium Series 1-2-3PH
- From 15A to 700A
- Max. voltage 480VAC or 600VAC
- cUL us is available as an option
- Heater Break alarm option
- Firing Zero Crossing and Burst firing
CD Automation
Multidrive 2PH Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
Multidrive 2PH Thyristor Power Controller
- From 45 up to 2700A
- Max. voltage 480V or 600V & 690V AC as an option
- Load type: Inductive Load, Transformer and Pure Resistance Element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Burst Firing, Delay Triggering + Burst Firing (DT)
- N°4 Retransmission are available plus IO
CD Automation
REVO M 2PH Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
REVO M 2PH Thyristor Power Controller
- From 30 up to 700A
- Max. voltage 480V or 600V AC as option
- (690V available on units > 280A)
- Load type: Resistance, IR Lamp short waveform and SiC element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Heather Break is available as an option.
- Firing mode: Burst Firing as standard
CD Automation
REVO Temperature and Power Controller
Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
REVO TC 2PH Temperature and Power Controller
- Suitable for Normal Resistance
- Three Phase 2PH (2-Leg) From 30A to 210A
- Max. voltage 480V, 600Vac
- Load type: Resistance
- Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
- Heather Break alarm options
- Firing mode: Zero Crossing
3PH Solid State Relays and Thyristor Power Controllers
CD Automation
REVO E 3PH
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
REVO E 3PH
- From 35 up to 500A
- Max. voltage 480V or 600V AC as option
- Designed to drive resistive, transformer loads and MoSi2 Elements
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: zero crossing, burst firing, single cycle, soft start + burst firing and phase angle + soft start
- N°1 Retransmission is available
CD Automation
CD 3000M 3PH
Universal input signal (SSR, 0-10V, 4-20mA, 10K Pot)
CD3000M 3PH
- Premium Series 1-2-3PH
- From 15A to 500A
- Max. voltage 480VAC or 600Vac
- cUL us is available as an option
- Heater Break alarm options
- Firing Zero Crossing or Burst Firing
CD Automation
Multidrive 3PH Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
Multidrive 3PH Thyristor Power Controller
- From 35 up to 2700A
- Max. voltage 480VAC, 600VAC or 690VAC as option
- Load type: Inductive Load, Transformer and MoSi2 element.
- Inputs: 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Singe Cycle, Burst Firing, Soft Start with Burst firing, Delay Triggering + Burst Firing (DT), Phase Angle (PA) or Soft Start + Phase Angle (S+PA); Current Limit is available with Phase Angle
CD Automation
REVO M 3PH Thyristor Power Controller
Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
REVO M 3PH Thyristor Power Controller
- From 30 up to 500A
- Max. voltage 480V or 600V AC as option
- (690V available on units > 280A)
- Load type: Resistance, IR Lamp short waveform and SiC element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Heather Break is available as an option.
- Firing mode: Burst Firing as standard
CD Automation
REVO Temperature and Power Controller
Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
REVO TC 3PH Temperature and Power Controller
- Suitable for Normal Resistance
- Three Phase 3PH (3-Leg) From 30A to 210A
- Max. voltage 480V, 600Vac
- Load type: Resistance
- Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
- Heather Break alarm options
- Firing mode: Zero Crossing