{"id":778,"date":"2016-04-25T09:34:41","date_gmt":"2016-04-25T08:34:41","guid":{"rendered":"http:\/\/test.tmcinstruments.nl\/en\/?post_type=portfolio&#038;p=778"},"modified":"2022-12-12T14:44:11","modified_gmt":"2022-12-12T13:44:11","slug":"sintrol-process-monitor-s305","status":"publish","type":"portfolio","link":"https:\/\/tmcinstruments.nl\/en\/portfolio\/sintrol-process-monitor-s305\/","title":{"rendered":"Sintrol Process Monitor S305"},"content":{"rendered":"\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_one_third-96e5bc8f1bd31f7745d9d1e4d1185da5\">\n.flex_column.av-av_one_third-96e5bc8f1bd31f7745d9d1e4d1185da5{\nborder-radius:15px 15px 15px 15px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-av_one_third-96e5bc8f1bd31f7745d9d1e4d1185da5 av_one_third  avia-builder-el-0  el_before_av_two_third  avia-builder-el-first  first flex_column_div av-zero-column-padding  '     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_image-39e5b2bb785e3e39cb9ca0ef74758144\">\n.avia-image-container.av-av_image-39e5b2bb785e3e39cb9ca0ef74758144 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-av_image-39e5b2bb785e3e39cb9ca0ef74758144 .av-caption-image-overlay-bg{\nopacity:0.4;\nbackground-color:#000000;\n}\n.avia-image-container.av-av_image-39e5b2bb785e3e39cb9ca0ef74758144 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-av_image-39e5b2bb785e3e39cb9ca0ef74758144 av-styling- av-hover-grow avia-align-center  avia-builder-el-1  avia-builder-el-no-sibling  noHover av-overlay-on-hover'   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><div class=\"av-image-caption-overlay\"><div class=\"av-caption-image-overlay-bg\"><\/div><div class=\"av-image-caption-overlay-position\"><div class=\"av-image-caption-overlay-center\"><p>QAL1 certified stack monitor<\/p>\n<\/div><\/div><\/div><img decoding=\"async\" fetchpriority=\"high\" class=\"wp-image-707 avia-img-lazy-loading-not-707 avia_image \" src=\"https:\/\/tmcinstruments.nl\/wp-content\/uploads\/2016\/03\/sintrol-dust-monitor-s305-750x603.jpg\" alt=\"\" title=\"sintrol-dust-monitor-s305-750x603\" height=\"603\" width=\"750\" itemprop=\"thumbnailUrl\" srcset=\"https:\/\/tmcinstruments.nl\/wp-content\/uploads\/2016\/03\/sintrol-dust-monitor-s305-750x603.jpg 750w, https:\/\/tmcinstruments.nl\/wp-content\/uploads\/2016\/03\/sintrol-dust-monitor-s305-750x603-300x241.jpg 300w, https:\/\/tmcinstruments.nl\/wp-content\/uploads\/2016\/03\/sintrol-dust-monitor-s305-750x603-705x567.jpg 705w, https:\/\/tmcinstruments.nl\/wp-content\/uploads\/2016\/03\/sintrol-dust-monitor-s305-750x603-450x362.jpg 450w\" sizes=\"(max-width: 750px) 100vw, 750px\"><\/div><\/div><\/div><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_two_third-2a64de42b738552fe666ca889af77e28\">\n.flex_column.av-av_two_third-2a64de42b738552fe666ca889af77e28{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-av_two_third-2a64de42b738552fe666ca889af77e28 av_two_third  avia-builder-el-2  el_after_av_one_third  el_before_av_one_full  flex_column_div av-zero-column-padding  '     ><p>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_heading-a81d729d4d6ef09d83cb8c26cb92e8f1\">\n#top .av-special-heading.av-av_heading-a81d729d4d6ef09d83cb8c26cb92e8f1{\npadding-bottom:10px;\n}\nbody .av-special-heading.av-av_heading-a81d729d4d6ef09d83cb8c26cb92e8f1 .av-special-heading-tag .heading-char{\nfont-size:25px;\n}\n.av-special-heading.av-av_heading-a81d729d4d6ef09d83cb8c26cb92e8f1 .av-subheading{\nfont-size:15px;\n}\n<\/style>\n<div  class='av-special-heading av-av_heading-a81d729d4d6ef09d83cb8c26cb92e8f1 av-special-heading-h3 blockquote modern-quote  avia-builder-el-3  el_before_av_textblock  avia-builder-el-first '><h3 class='av-special-heading-tag'  itemprop=\"headline\"  >QAL1 certified stack monitor for official emissions measurements<\/h3><div class=\"special-heading-border\"><div class=\"special-heading-inner-border\"><\/div><\/div><\/div><br \/>\n<section  class='av_textblock_section av-av_textblock-0366cc7376be6c9e82a3e9cc8987b64f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><p>QAL1 certified by TUV to meet the EN 14181 standard, the S305 dust monitor is used for official emissions applications. The state of the art dust monitor has been used in stack emissions for a number of state owned and private industrial applications around the world.<\/p>\n<p>Utilizing our unique Inductive Electrification principle, the S305 brings the reliability the government requires and combines it with the convenience plant operators expect from a particulate measurement device. With minimal maintenance required, this is an optimal solution for plant operators needing to measure stack dust emissions for government control..<\/p>\n<p><strong>ATEX Models<\/strong><\/p>\n<ul>\n<li>Certified for ATEX Zone 20, 21 or 22<\/li>\n<li>Approved to Category II 1\/2 for Gas and Dust<\/li>\n<li>IP65 Enclosure, Custom Designed \u25cf Certification Type: II 1\/2 GD EEx ia IIC, T6, IP65, 85\u00b0C<\/li>\n<li>Utilizing SINTROL\u2019s Advanced Inductive Electrification Technology<\/li>\n<\/ul>\n<p>The ATEX directive covers health and safety of workers potentially at risk from exposure to explosive environments. This directive classifies areas into Zone 0, 1, 2 for gas and 20, 21 or 22 for dust and guides plant operators to install the appropriate ATEX certified systems. Products are required to be categorized by the level of protection that they offer against the risk of them becoming a potential source of ignition in an explosive atmosphere. The equipment conformity categories are 1, 2 &amp; 3.<\/p>\n<\/div><\/section><\/p><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_one_full-352b07ef7d3bc99b2e9f92e7a9e06bdb\">\n.flex_column.av-av_one_full-352b07ef7d3bc99b2e9f92e7a9e06bdb{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-av_one_full-352b07ef7d3bc99b2e9f92e7a9e06bdb av_one_full  avia-builder-el-5  el_after_av_two_third  el_before_av_hr  first flex_column_div av-zero-column-padding  column-top-margin'     ><div  class='avia-button-wrap av-lbkujhwi-407cbfa2b2bfe88d1bc61ac910e75205-wrap avia-button-right  avia-builder-el-6  avia-builder-el-no-sibling '><a href='https:\/\/tmcinstruments.nl\/en\/sintrol-archive\/'  class='avia-button av-lbkujhwi-407cbfa2b2bfe88d1bc61ac910e75205 av-link-btn avia-icon_select-yes-left-icon avia-size-large avia-position-right av-icon-on-hover avia-color-theme-color'  ><span class='avia_button_icon avia_button_icon_left' aria-hidden='true' data-av_icon='\ue830' data-av_iconfont='entypo-fontello'><\/span><span class='avia_iconbox_title' >Back to Sintrol Archive<\/span><\/a><\/div><\/div>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_hr-5ea7596238ed9f191e6b5e662093052f\">\n#top .hr.hr-invisible.av-av_hr-5ea7596238ed9f191e6b5e662093052f{\nheight:30px;\n}\n<\/style>\n<div  class='hr av-av_hr-5ea7596238ed9f191e6b5e662093052f hr-invisible  avia-builder-el-7  el_after_av_one_full  el_before_av_tab_container '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><\/p>\n<div  class='tabcontainer av-av_tab_container-0bacd910096d11a3cec6dfb538798966 top_tab  avia-builder-el-8  el_after_av_hr  avia-builder-el-last ' role='tablist'>\n<section class='av_tab_section av_tab_section av-av_tab-8d3b58d3651858c5f61433b722e406e3'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='tab active_tab' role='tab' tabindex='0' data-fake-id='#tab-id-1' aria-controls='tab-id-1-content'  itemprop=\"headline\" ><span class='tab_icon' aria-hidden='true' data-av_icon='\ue8df' data-av_iconfont='entypo-fontello'><\/span>Technical Details<\/div><div id='tab-id-1-content' class='tab_content active_tab_content' aria-hidden=\"false\"><div class='tab_inner_content invers-color'  itemprop=\"text\" ><h3>S300 Series dust monitors<\/h3>\n<table class=\"tabel_sintrol\">\n<tbody>\n<tr>\n<td>Measurement Objects<\/td>\n<td>Solid particles in gas flow<\/td>\n<\/tr>\n<tr>\n<td>Particle Size<\/td>\n<td>0.3 \u00b5m or larger<\/td>\n<\/tr>\n<tr>\n<td>Measurement Range<\/td>\n<td>From 0.1 mg\/m\u00b3<\/td>\n<\/tr>\n<tr>\n<td>Measurement Principle<\/td>\n<td>Inductive Electrification<\/td>\n<\/tr>\n<tr>\n<td>Protection Category<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Probe\u00a0Length (total\/measuring)<\/td>\n<td>500mm\/440mm, 750mm\/690mm (optional),1000mm\/940mm (optional), others on request19.7&#8243; \/ 17.3&#8243;, 29.5&#8243; \/ 27.2&#8243;, 39.4&#8243; \/ 37.0&#8243; (optional), others on request<\/td>\n<\/tr>\n<tr>\n<td>Power Supply<\/td>\n<td>115 VAC, 230 VAC or 24 VDC<\/td>\n<\/tr>\n<tr>\n<td>Power Consumption<\/td>\n<td>DC model Max 3 W, AC model Max 8 W<\/td>\n<\/tr>\n<tr>\n<td>Wiring Connections &#8211; Power Supply<\/td>\n<td>DIN PG11 cable gland<\/td>\n<\/tr>\n<tr>\n<td>Wiring Connections &#8211; Output Signals<\/td>\n<td>DIN PG11 cable gland<\/td>\n<\/tr>\n<tr>\n<td>Process Connection<\/td>\n<td>Socket (38 mm OD), quick clamp (optional), flange (optional)<\/td>\n<\/tr>\n<tr>\n<td>Output Signals<\/td>\n<td>&#8211; Two SPDT relays: 5A, 24V AC\/DC<\/td>\n<\/tr>\n<tr>\n<td>Communication Interface<\/td>\n<td>Serial Communication RS-485<\/td>\n<\/tr>\n<tr>\n<td>Range Set Up<\/td>\n<td>&#8211; Normal measuring range: automatic, based on average measured dust flow during setup procedure<br \/>\n&#8211; Extended measuring range: User selectable<\/td>\n<\/tr>\n<tr>\n<td>Relay Alarm Settings<\/td>\n<td>\n<div>&#8211; Automatic, set at factory: Based on average measured dust flow<\/div>\n<div>&#8211; User selectable ranges<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Offset Trim<\/td>\n<td>Automatic drift compensation<\/td>\n<\/tr>\n<tr>\n<td>Signal Damping Time<\/td>\n<td>0 &#8211; 300 s<\/td>\n<\/tr>\n<tr>\n<td>Relay Delay Time<\/td>\n<td>0 &#8211; 180 s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Process Conditions<\/h3>\n<table class=\"tabel_sintrol\">\n<tbody>\n<tr>\n<td>Temperature<\/td>\n<td>\n<div>Max 300\u00b0C, Max\u00a0700\u00b0C (optional)<\/div>\n<div>Max 572 \u00b0F, Max 1292 \u00b0F (optional)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Pressure<\/td>\n<td>\n<div>Max 200 kPa, Max 600 kPa (optional)<\/div>\n<div>Max 43.5 PSI, Max 87 PSI (optional)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>Gas Velocity<\/td>\n<td>Min 4m\/s \u00a0\u0131 \u00a0Min 13.1 ft\/s<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td>Max 95% RH (non-condensing)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Ambient Conditions<\/h3>\n<table class=\"tabel_sintrol\">\n<tbody>\n<tr>\n<td>Temperature<\/td>\n<td>-20 to +45\u00b0C and to 60\u00b0C for 24 VDC-4 to 113 \u00b0F and to 140 \u00b0F for 24 VDC<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td>Max 95% RH (non-condensing)<\/td>\n<\/tr>\n<tr>\n<td>Vibration<\/td>\n<td>Max 5 m\/s\u00b2 \u00a0\u0131 \u00a0Max 16.4 ft\/s2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Materials<\/h3>\n<table class=\"tabel_sintrol\">\n<tbody>\n<tr>\n<td>Probe (wetted part)<\/td>\n<td>Stainless steel (AISI 316L)<\/td>\n<\/tr>\n<tr>\n<td>Probe\u00a0Coating\u00a0(wetted part)<\/td>\n<td>PTFE Teflon (optional)<\/td>\n<\/tr>\n<tr>\n<td>Process Connection\u00a0(wetted part)<\/td>\n<td>Stainless steel (AISI 316L)<\/td>\n<\/tr>\n<tr>\n<td>Probe\u00a0Insulation \u00a0(wetted part)<\/td>\n<td>PEEK<\/td>\n<\/tr>\n<tr>\n<td>Probe Sealing (wetted part)<\/td>\n<td>FPM Viton<\/td>\n<\/tr>\n<tr>\n<td>Enclosure<\/td>\n<td>Aluminum alloy<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>2.3kg \u00a0\u0131 \u00a05.1 lbs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><\/div><\/section>\n<section class='av_tab_section av_tab_section av-av_tab-c9a2040cf93d093f7bec25f8badc8c31'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='tab' role='tab' tabindex='0' data-fake-id='#tab-id-2' aria-controls='tab-id-2-content'  itemprop=\"headline\" ><span class='tab_icon' aria-hidden='true' data-av_icon='\ue84e' data-av_iconfont='entypo-fontello'><\/span>Documentation<\/div><div id='tab-id-2-content' class='tab_content' aria-hidden=\"true\"><div class='tab_inner_content invers-color'  itemprop=\"text\" ><div class=\"portfolio_list\">\n<ul>\n<li><a class=\"portfolio_pdf\" href=\"\/wp-content\/uploads\/assets\/sintrol\/sintrol-s300_series_brochure.pdf\" target=\"_blank\" rel=\"noopener\">Download the brochure<\/a><\/li>\n<li><\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":707,"comment_status":"open","ping_status":"closed","template":"","tags":[],"portfolio_entries":[526],"class_list":["post-778","portfolio","type-portfolio","status-publish","has-post-thumbnail","hentry","portfolio_entries-sintrol-archive-old-models-en"],"_links":{"self":[{"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/portfolio\/778","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/types\/portfolio"}],"replies":[{"embeddable":true,"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/comments?post=778"}],"version-history":[{"count":0,"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/portfolio\/778\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/media\/707"}],"wp:attachment":[{"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/media?parent=778"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/tags?post=778"},{"taxonomy":"portfolio_entries","embeddable":true,"href":"https:\/\/tmcinstruments.nl\/en\/wp-json\/wp\/v2\/portfolio_entries?post=778"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}